JC090 Remote type Pipe Magnetic Flow meter

JC090 Remote type Pipe Magnetic Flow meter is a kind of inductional instrument designed by Faraday’s law of electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of insertion of single chip to realize digital excitation and employs CAN local fieldbus.

Product Description

JC090 Remote type Pipe Magnetic Flow meter  


Electromagnetic flowmeter is a kind of inductional instrument designed by Faraday’s law of electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of insertion of single chip to realize digital excitation and employs CAN local fieldbus.   

Electromagnetic flow meter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control. Electromagnetic flow meters are widely used in industrial sectors such as chemical industry, environmental protection, metallurgy, pharmaceutical, paper making, water supply and removal etc.

Besides measuring flow of general conductive liquid electromagnetic flowmeter can measure flow of liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid and strong alkali.

 

Smart electromagnetic flow meters consist of sensor and smart signal transducer. And it can be classified into two structures--- integral type and remote type according to the set-up form of the sensor and transducer. In terms of integral type electromagnetic flow meters, transducer and sensor directly assembles as a whole and can not be dissociated. It is usually used at the scene where the environmental situation is good. To remote type electromagnetic flow meters transducer composes a product through a special electric cable and sensor. The sensor is installed at the scene and the transducer is installed in the place where the conditions are good. It is usually used at the scene where the environmental situation is poor, such as underground wells, high temperature and the place where people can not reach.


magnetic-flow-meter.jpg

 



Technial Parameter

Technical Parameter for JC090 Remote type Pipe Magnetic Flow meter 


Suitable Diameter

DN10~DN2600 (below DN25 non-standard,which should be customized)

Electrodes Materials

316L (stainless steel), Hastelloy C, Hastelloy B, Titanium, Tantalum

Suitable Fluid

Liquid with conductive ratio more than 5 μs/cm

Measuring Range

0.1~10m/s (extendable to 15m/s)

Upper Limit of Span

0.5~10m/s. 1~5m/s recommended

Accuracy

0.3%, 0.5%,1.0%

Output Signals

4~20mADC, load<= 750ohm, 0~3kHz, 5V with source and changeable width.

high terminal and effective frequency output , RS485 interface

Operation Pressure

1.0MPa, 1.6MPa, 4.0MPa, 16MPa (special)

Fluid Temperature

-20C~80C, 80C~130C,130C~180C Depending on Lining Material

Ambient Temperature

Sensor -40C~80C. transducer -15C~50C

Ambient Humidity

<= 85%RH (at 20C)

Cable Outlet Size

M20(16) ×1.5,1/2”NPT

Power Supply

220VAC±10%, 50Hz±1Hz, 24VDC±10%

Power Consumption

<=8W

Protection Ratings

Integral type: IP65. remote type: sensor IP68,transducer IP65

Materials of Liner

PTFE, soft rubber, hard rubber, PFA, etc

Process Connection

Flange :ANSI , DIN , JIS ,ISO ,GB standard

Thread :NPT ,BSP ,G

Tri-clamp connection

Earthing Materials

316L (stainless steel), HC, Ti, Ta, Cu

Housing Material

Carbon steel , 304SS , 316SS 


Model Selection

Model Selection for JC090 Remote type Pipe Magnetic Flow meter 


CodeNominal Diameter
(mm)
Flow Range
(m3/h)
CodeNominal Diameter (mm)Flow Range
(m3/h)
JC-090-10
JC-090-15
JC-090-20
JC-090-25
JC-090-32
JC-090-40
JC-090-50
JC-090-65
JC-090-80
JC-090-100
JC-090-125
JC-090-150
JC-090-200
JC-090-250
JC-090-300
JC-090-350
JC-090-400
Dn10
DN15
DN20
DN25
DN32
DN40
DN50
DN65
DN80
DN100
DN125
DN150
DN200
DN250
DN300
DN350
DN400
0.085-2.8
0.19~6.36
0.34~11.3
0.53~17.66
0.87~28.94
1.36~45.22
2.12~70.65
3.58~119.40
5.43~180.86
8.48~282.6
13.25~441.56
19.08~635.85
33.91~1130.40
52.99~1766.25
76.30~2543.40
103.86~3461.85
135.65~4521.60
JC-090-450
JC-090-500
JC-090-600
JC-090-700
JC-090-800
JC-090-900
JC-090-1000
JC-090-1200
JC-090-1400
JC-090-1600
JC-090-1800
JC-090-2000
JC-090-2200
JC-090-2400
JC-090-2600
DN-450
DN-500
DN-600
DN-700
DN-800
DN-900
DN-1000
DN-1200
DN-1400
DN-1600
DN-1800
DN-2000
DN-2200
DN-2400
DN-2600
171.00~5722.65
211.95~7065.00
305.21~10173.00
415.42~13847.40
542.59~18086.40
686.72~22890.60
847.80~28260.00
1220.83~40694.40
1661.69~55389.60
2170.37~72345.60
2746.87.00~91562.40
3391.20~113040.00
4103.35~136778.40
4883.33~162777.60
5731.13~191037.60


Code

Electrode Material

K1
K2
K3
K4
K5
K6
K7

SS 316L
Hastelloy B
Hastelloy C
Titanium
Tantalum
Pt/Iridium Alloy
Stainless Steel Painting Tungsten Carbide


Code  

Material of liner


C1
C2
C3
C4
C5
C6
C7

PTFE (F4 or Teflon)
Fluorinated Ethylene Propylene (FEP)
Fs
PO (Soft Rubber)
Polyurethane Rubber (PUR)
Hard Rubber
PFA



Code

Function

E1
E2
E3
F1
F2

F3
F4
T1
T2
T3
P1
P2
P3
P4
P0
D1
D2
D3
J1
J2
J3
W1
W2
W3

Class 0.3%
Class 0.5%
Class 1.0%
4~20mADC, load ≤750Ω
0~3kHz, 5V active, changeable pulse, high-terminal and effective frequency output
RS 485 interface (Modbus)
HART
Normal Temperature
High Temperature
Ultra Temperature
1.0MPa
1.6MPa
4.0MPa
16MPa
Special Pressure
220VAC+10%; 50Hz+ 1Hz
24VDC+10%
Battery Operated
Integral Type
Remote Type
Explosion-proof, Integral
Flange connection (standard: ANSI, JIS, DIN, GB)
Thread connection (NPT, BSP, G)
Sanitary Tri-clamp connection




How to to order

How to order 


1.Medium

2.Pipe size

3.Flow rate (min/normal/max)

4.Working temperature

5.Working pressure

6.Process connection

7.Power supply

8.Other special requirement


Video

None

+86 150 5269 9328 emilyxyd info@bcstgroup.com sales@bcstgroup.com 2673306572 Emily_bcst

Emily_bcst