multi variable pressure transmitter JCMT is suitable to measure liquid, gas, or steam flow and differential pressure. RP1005 outputs a 4~20mADC / Modbus RS485 / HART / Pulse signal corresponding to the measured flow or differential pressure. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored

Product Description

JCMT Multivariable Transmitter with temperature sensor 

The multi variable pressure transmitter JCMT is suitable to measure liquid, gas, or steam flow and differential pressure. JC1005 outputs a 4~20mADC / Modbus RS485 / Pulse signal corresponding to the measured flow or differential pressure. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via different communications. Other key features include quick response, remote set-up using communications, selfdiagnostics and optional status output for pressure high/low alarm.

multi-variable -pressure -transmitter.jpg

Technical Parameter

Technical Parameter for  Multi variable pressure transmitter 


1 PERFORMANCE SPECIFICATIONS

Reference Accuracy of Calibrated Span (includes terminal-based linearity, hysteresis, and repeatability)± 0.075%/± 0.01%

If TD>10 (TD=URL/SPAN): ±(0.0075×TD)%/ ±(0.01×TD)%

Ambient Temperature Effects

-2065±(0.15×TD+0.05)%×Span

Every 10is ±0.08% ×Span (TD=1)

-40-20& 6585

±(0.2×TD+0.05)%×Span

Static Pressure Effects

±(0.05%URL+0.075%Span)/10MPa

Overpressure Effects: ±0.1%×Span /10MPa

Stability: ±0.1%×Span /3 years

Power Supply Effects

±0.001% /10V (1242V DC)

Measuring Temperature

-50650

Zero Adjustment Limits

Zero can be fully elevated or suppressed, within the lower and upper range limits of the capsule.

External Zero Adjustment

External zero is continuously adjustable with 0.01% incremental resolution of span. Re-range can be done locally using the range setting switch.

Mounting Position Effects

Rotation in diaphragm plane has no effect. Tilting up to 90 degree will cause zero shift up to 0.4 kPa which can be corrected by the zero adjustment.

Output

Two wire 4~20mADC (Output range: 3.9 mA to 20.5 mA.),

Modbus RS485, HART FSK protocol on 4~20mADC signal,  Pulse signal output .

Failure Alarm (the mode can be selected)

Low Mode (min): 3.7 mA

High Mode (max): 21 mA

No Mode (hold): Keep the effective value before the fault. Note: The standard setting of failure alarm is High

Mode.

Response Time

The amplifier damping constant is 0.1 sec; The sensor damping constant is 0.1~1.6 sec, it depends on the range and range compression ratio. Amplifier damping

time constant is adjustable from 0.1 to 60 sec by software and added to response time.

UpTime < 15s

Ambient Temperature Limits

-40 to 85°C

-20 to 65°C with LCD display or fluorine rubber sealing

Storage and Transportation Temperature Limits

-50 to 85°C; -40 to 85°C with LCD display

Working Pressure Limits (Silicone oil)

Maximum working pressure: 0.25MPa, 2MPa, 10MPa ,40MPa

Static Pressure Limits

3.5kPa abs. to maximum working pressure.

One-way Overload Pressure Limit

The maximum one-way overload pressure is maximum working pressure.

Electromagnetic Compatibility (EMC)

Look the EMC Performance Table

3 INSTALL

Supply & Load Requirements

24 V DC supply, R(Us-12V)/Imax kΩ, Imax=23 mA.

Maximum voltage limited: 42VDC, Minimum voltage limited: 12VDC, 15VDCwith LCD display) 230Ω to 600Ω for digital communication

Electrical Connection

The electrical connection is made via cable entry M20x1.5.The screw terminals are suitable for wire  cross-sections up to 2.5mm2.

Process4 PHYSICAL SPECIFICATIONS

Wetted Parts Materials

Sensor Body 316L stainless steel

Isolating Diaphragm316L stainless steel / Hastelloy

C/Gold plated on 316L/FEP plated on 316L/Tantalum

Cover Flange 316 stainless steel

Nuts and Bolts 304 stainless steel

Process Connector 316 stainless steel

Fill fluid Silicone oil/Fluorinated oil

Process Connector GasketPerbunanNBR/Viton

FKM/Teflon(PTFE)

Amplifier Housing Aluminum with epoxy resin coat

Housing Gasket PerbunanNBR

Name plate and tag304 stainless steel

Weight 3.3kg

Degrees of Protection: IP67 


Model Selection

Model selection 


Multi-variable Pressure Transmitter JCMT

Accuracy

B

Reference Accuracy±0.075%

C

Reference Accuracy±0.1%


Span



B

0-200Pa6kPa0-20600 mmH2O/(0-260mbar)

C

0-1kPa40kPa0-1004000 mmH2O/(0-10400mbar)

D

0-2.5kPa250kPa0-0.2525 mH2O/(0-252500mbar)

F

0-30kPa3MPa0-3300 mH2O/(0-0.330bar)

Static pressure sensor


1

0.25 MPa


2

2MPa


3

20MPa


4

40MPa


Diaphragm fill fluid


A

316L stainless steel Silicone oil


B

316L stainless steel Fluorinated oil


C

Hastelloy C Silicone oil


D

Hastelloy C Fluorinated oil


E

Gold plated on 316L Silicone oil


F

Gold plated on 316L Fluorinated oil

G

FEP plated on 316L Silicone oil


T

Tantalum Silicone oil


Process connections

N

7/16-20 UNF and 1/4-18 NPT female thread, No relief valve

B

7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at end of flanges

U

7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of the flange side

D

7/16-20 UNF and 1/4-18 NPT female thread, Relief valve at the lower part of

the flange side

Process connector gasket

N

PerbunanNBR


F

Viton (FKM)


P

Teflon (PTFE)


Special function



N

None


O

Degrease cleansing treatmentOxygen measurement must be

with fluorinated oil filled capsule, Viton (FKM) gasket,

<6MPa ,<60)

P

Anti-lightning function


Mounting bracket

N

None


1

304 stainless steel


2

Carbon steel galvanized


Process connector accessory

N

None


1

Stainless steel oval-shaped flange with 1/2 NPT  female thread

2

Stainless steel D-shaped connector with M20x1.5 male thread

Integral indicator



N

None


1

LCD display


2

Backlit LCD display


Configuration



N

None


A

Configure by customer table


Output



H

HART with 4~20mADC


M

Modbus RS485


P

Pulse signal



How to order

How to order multi variable pressure transmitter JCMT 


  1. Medium 

  2. Range 

  3. Working pressure 

  4. Working temperature 

  5. Static pressure 

  6. Other requirement 